ST-30:Standard Specifications
1. Spout installation capacity | <Record> 60 pieces/min (Pouch composition : PET12/NY15/LLDPE80)*1 |
---|---|
2. Spout installation position and Pouch size range |
20-90 Degrees (90 degrees is at top position of the pouch) |
3. Requirements | Power supply : 3-phase 200V AC, Approx. 35.2A, 12.2KVA Compressed air : 0.6MPa(6kgf/cm2), Air consumption : Approx. 600L/min.(ANR) (Requires a separate air compressor of 5.5 kw [7 HP] or more.) Cooling water : Approx. 5L/min. |
4. Required floor space | Approx. 3.3 x 4.7m *Allow extra space for maintenance and operating. |
5. Attached equipment | •Parts feeder for spout (With a 100L hopper) •Pouch infeed conveyor •Spouted pouch discharge conveyor (Standard length: 3m) |
* Due to equipment improvement, the above-mentioned figures and appearance may be changed without notice.
Contact Us
Options, in addition to those mentioned above, can be designed and manufactured to suit customer needs. Please consult us without obligation.
- North & South America
- Other
- +1-920-632-7319
- +1-920-632-7361
If you would like more information about us or any inquiries, please contact in the form.